Silent X-Stream™  Panel Coolers

PRODUCT OVERVIEW

The Silent X-Stream™ Frigid-X™ Panel Cooler series for electronic control panels provide a low cost method of both purging and cooling electrical and electronic control panels by using a stainless steel vortex tube to create cold air from ordinary compressed air. Utilizing a hot and cold end muffling kit the unit is made extra quiet to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat. The hot air is exhausted safely underneath the hot end muffler.

The  Silent X-Stream™ Frigid-X™ Panel Cooler series are compact and can be installed in minutes through a standard electrical knockout. There are virtually no moving parts.

 

* US patent number 8,616,010 / Other  countries: Patented or Patent Pending

Note: Always question non-approved units used on electrical enclosures to assure that your panels are not damaged by inferior products.

 

Features

  • Low in cost
  • Compact
  • No CFC’s
  • Fast installation
  • Stabilize enclosure temperature and humidity
  • Virtually maintenance free (No Moving Parts)
  • Mounts in a standard electrical knockout
  • Stops heat damage and nuisance tripping
  • Eliminates fans and filters
  • Prevents dirt contamination by keeping enclosure at positive pressure
  • Units applicable to all environments including high temperature to 200ºF

VIDEOS

DIMENSIONS

Contact Nex Flow™ for assistance in sizing cabinet enclosure cooler – Frigid-X series. See Below for Sizing Specifications

MODEL NO. VERSION
61104X NEMA Type 4-4X (IP-66) Continuous Operation 290
(85)
61108X NEMA Type 4-4X (IP-66) Continuous Operation 580
(170)
61115X NEMA Type 4-4X (IP-66) Continuous Operation 1100
(322)
61125X NEMA Type 4-4X (IP-66) Continuous Operation 1800
(527)
61130X NEMA Type 4-4X (IP-66) Continuous Operation 2100
(615)
61140X NEMA Type 4-4X (IP-66) Continuous Operation 2900
(849)
63104X NEMA type 4-4X (IP-66) on-off conttrol 290
(85)
63108X NEMA Type 4-4X (IP-66) on-off control 580
(170))
63115X NEMA Type 4-4X (IP-66) on-off control 1100
(322)
63125X NEMA Type 4-4X (IP-66) on-off control 21800
(527)
63130X NEMA Type 4-4X (IP-66) on-off control 2100
(615)
63140X NEMA Type 4-4X (IP-66) on-off control 2900
(849)
60115X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 1100
(322)
60125X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 21800
(527)
60130X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 2100
(615)
60140X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 2900
(849)

 

** In 316 environments normally customers will have special filtration systems for such environments already.

 

*Cooling effect based on 95°F temperature inside cabinet, 100 PSIG (6.9 BAR) compressor inlet pressure, and 70ºF (21ºC) inlet temperature.

BTU/hr. figures rounded to nearest 100 BTU/hr (1 WATT).

All Continuous Operation models include the cooling unit, filter with auto drain and cold air distribution kit.

All On-Off control units include the cooling unit, filter with auto drain, cold air distribution kit, solenoid valve and thermostat.

SELECTION

Panel Coolers, Panel Cooler, Panel Air Conditioner, Cabinet Enclosure Cooler, Electrical Panel Air Conditioners, Cabinet Cooling Solution, Cooler Master Cabinet, Panel Air Conditioner, Adjustable Thermostat, Electrical Panel Coolers, How to Cool Electrical Enclosures, Electronic Temperature Control

Silent X-Stream™ NEMA 12 (IP56) Quiet Panel Coolers

Silent X-Stream™ NEMA 12 (IP56) Quiet Panel Coolers for standard cabinet enclosures and panels. All units 303/304 stainless steel for corrosive environments and long life. Super quiet to about 64 dBA. Utilizing a hot and cold end muffling kit the unit is made extra quiet to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat.

Silent X-Stream™ NEMA 3R (IP14) Quiet Panel Coolers

Silent X-Stream™ NEMA 3R (IP14) Quiet Panel Coolers for cabinet enclosures and panels in outdoor use. All units 303/304 stainless steel for corrosive environments and long life. Super quiet to about 64 dBA. Utilizing a hot and cold end muffling kit the unit is made extra quite to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat.

 

Silent X-Stream™ NEMA 4-4x (IP66) Quiet Panel Coolers

Silent X-Stream™ NEMA 4-4x (IP66) Quiet Panel Coolers for cabinet enclosures and panels in wash down applications. All units 303/304 stainless steel for corrosive environments and long life. Super quiet to about 64 dBA. Utilizing a hot and cold end muffling kit the unit is made extra quiet to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat.

 

Options

By-Pass System for Panel Coolers

Frigid-X™ By-Pass System for Panel

In very dirty environments, it can be advantageous to have a small amount of compressed air entering the control panel when the panel cooler is not operating (turned off utilizing a solenoid and thermostat package to conserve energy).  This is a “constant purge” system that will keep the control panel at a  slightly positive pressure all the time to prevent dirty environmental air from entering, thereby keeping the control panel clean.

Electronic Control Digital Thermostat

Electronic Temperature Control

Electronic Thermostat ELC (Electronic Control Digital Thermostat) is a way for precise control of one or two Nex Flow™ Frigid-X™ cabinet panel coolers.

Mechanical Thermostat

Mechanical Thermostat And Solenoid Valve Kit

This kit comes complete with a solenoid valve, thermostat, and a resistor. The resistor is included should you encounter rapid temperature fluctuations in the control panel causing the solenoid to cycle on and off to quickly (chattering). The resistor is installed (if needed) across the leads of the thermostat and prevents chattering by dampening the thermo switch sensitivity.

Side Mount Kit for Cabinet Panel Coolers

Side Mount Kit for Cabinet Panel Coolers

If mounting cannot be on the top of the control panel an optional Side Mount Kit for Cabinet Panel Coolers is available (except for the 316L stainless units). Enclosure Cooling System must be mounted vertical either at the top or at the side using the side mount.

Calculating Head Load

Total heat load consists of the heat transfer from outside your panel and from the heat dissipated inside the control unit.

Useful terms and conversions:

1 BTU/hr = 0.293 watts
1 BTU/hr – 0.000393 horsepower
1 Watt = 3.415 BTU/hr
1 horsepower = 2544 BTU/hr
1 Watt = 0.00134 horsepower
1 Square Foot = 0.0929 square meters
1 Square Meter = 10.76 square foot

Typical fan capacity:

4″ fan: 100 CFM (2832 LPM)
6″ fan: 220 CFM (6230 LPM)
8″ fan: 340 CFM (9628 LPM)
10″ fan 550 CFM (15574 LPM)

BTU/hr. cooling effect from fan 1.08 x (temp. inside panel in °F – temp. outside panel in degrees F) x CFM.

Watts cooling effect from fan: 0.16 x (temp. inside panel in °C – temp. outside panel in degrees C) x LPM.

Calculating BTU/hr. or Watts:

  1. Determine the heat generated inside the enclosure. Approximations may be necessary. For example, if you know the power generated inside the unit, assume 10% of the energy is dissipated as heat.
  2. For heat transfer from the outside, calculate the area exposed to the atmosphere except for the top of the control panel.
  3. Choose the internal temperature you wish to have, and choose the temperature difference between it and the maximum external temperature expected.
  4. From the conversion table that follows, determine the BTU/hr. per square foot (or watts per square meter) for the temperature difference.
  5. Multiply the panel surface area times the BTU/hr. per square foot (or watts per square meter) to get the external heat transfer in BTU/hr or in watts.
  6. Sum the internal and external heat loads calculated.
  7. If you do not know the power used in the enclosure but you can measure temperatures, then measure the temperature difference between the outside at current temperature, and the present internal cabinet temperature.
  8. Note size and number of any external fans. Provide this information to Nex Flow™  to assist in sizing the appropriate cooling system.
Temperature Difference in °F BTU/hr./sq. ft. Temperature Difference in °C Watts/sq.m
5 1.5 3 5.2
10 3.3 6 11.3
15 5.1 9 17.6
20 7.1 12 24.4
25 9.1 15 31.4
30 11.3 18 39.5
35 13.8 21 47.7
40 16.2 24 55.6

Example:

The control panel coolers has two frequency drives totaling 10 horsepower and one module rated at 100 watts. The maximum outside temperature expected is 105°F or 40.5°C. The area of the control panel cooler exposed sides, except for the top is 42 square feet or 3.9 square meters. We want the internal temperature to be 95° or 35°C.

Total internal power is 10 hp x 746 watts/hp – 7460 plus 100 watts = 7560 watts.
Assume 10% forms heat = an internal heat load of 756 watts.

Or

Total internal power is 10 hp x 2544 BTU/hp = 25440 BTU/hr plus 100 watts x 3.415 BTU/hr/watt = 25782 BTU/hr.

Assume 10% forms heat = an internal heat load of 2578 BTU/hr.

External heat load: The temperature difference between the desired temperature and the outside is 10°F or 5.5°C. Using the conversions (and interpolating where necessary) we multiply the area by the conversion factor:

42 sq. ft x 3.3 – 139 BTU/hr or 3.9 sq. m x 10.3 = 40 watts

Total Heat Load: 756 + 40 – 796 watts or 2578 + 139 – 2717 BTU/hr.

You would use a Model 61040 for constant operation or a Model 63040 for one-off control. (Rated at 2900 BTU/hr or 849 watts).

FRIGID-X ELECTRONIC & ELECTRICAL ENCLOSURE COOLERS

PART NO. DESCRIPTION Size Price US Dollars
60102X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69005) $695.00
60102X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69005) $695.00
60102X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69005) $695.00
60110X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60115X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60125X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60130X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60140X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
63102X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $692.00
63104X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $692.00
63108X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $692.00
63110X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63115X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63125X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63130X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63140X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63102X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,105.00
63104X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,105.00
63108X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,105.00
63110X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63115X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63125X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63130X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63140X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00

Frigid-X™ By-Pass System for Panel cooler

PART NO. DESCRIPTION Size Price US Dollars
69700 BY-Pass System to make a contant purge systrem – One system for each cooler is necessary $180.00

MUFFING KITS FOR PANEL COOLERS

PART NO. DESCRIPTION Size Price US Dollars
69501 Cold End Muffler Kit for 10 to 40 SCFM Panel Cooler Units $90.00
69502 Hot End Muffler & Heat Guard Kit for 10 to 40 SCFM Panel Cooler Units $80.00
69503 Cold End Muffler Kit for 2 to 8 SCFM Panel Cooler Units $85.00
69504 Hot End Muffler & Heat Guard Kit for 2 to 8 SCFM Panel Cooler Units $75.00
69505 Hot and Cold End Muffler & Heat Guard Kit for 10 to 40 SCFM Panel Cooler Units $170.00
69506 Hot and Cold End Muffler & Heat Guard Kit for 2 to 8 SCFM Panel Cooler Units $160.00

Prices are in USA dollars – ex works Cincinnati, OH, USA for orders

in USA and Richmond Hill, ON, Canada for International orders.

Tel : +1-416-410-1313   Fax : +1-416-410-180 or +1-716-626-3001

website : www.nexflow.com

email : sales@www.nexflowdirect.com


+ Overview

PRODUCT OVERVIEW

The Silent X-Stream™ Frigid-X™ Panel Cooler series for electronic control panels provide a low cost method of both purging and cooling electrical and electronic control panels by using a stainless steel vortex tube to create cold air from ordinary compressed air. Utilizing a hot and cold end muffling kit the unit is made extra quiet to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat. The hot air is exhausted safely underneath the hot end muffler.

The  Silent X-Stream™ Frigid-X™ Panel Cooler series are compact and can be installed in minutes through a standard electrical knockout. There are virtually no moving parts.

 

* US patent number 8,616,010 / Other  countries: Patented or Patent Pending

Note: Always question non-approved units used on electrical enclosures to assure that your panels are not damaged by inferior products.

 

+ Features

Features

  • Low in cost
  • Compact
  • No CFC’s
  • Fast installation
  • Stabilize enclosure temperature and humidity
  • Virtually maintenance free (No Moving Parts)
  • Mounts in a standard electrical knockout
  • Stops heat damage and nuisance tripping
  • Eliminates fans and filters
  • Prevents dirt contamination by keeping enclosure at positive pressure
  • Units applicable to all environments including high temperature to 200ºF
+ Videos

VIDEOS

+ Dimensions

DIMENSIONS

Contact Nex Flow™ for assistance in sizing cabinet enclosure cooler – Frigid-X series. See Below for Sizing Specifications

MODEL NO. VERSION
61104X NEMA Type 4-4X (IP-66) Continuous Operation 290
(85)
61108X NEMA Type 4-4X (IP-66) Continuous Operation 580
(170)
61115X NEMA Type 4-4X (IP-66) Continuous Operation 1100
(322)
61125X NEMA Type 4-4X (IP-66) Continuous Operation 1800
(527)
61130X NEMA Type 4-4X (IP-66) Continuous Operation 2100
(615)
61140X NEMA Type 4-4X (IP-66) Continuous Operation 2900
(849)
63104X NEMA type 4-4X (IP-66) on-off conttrol 290
(85)
63108X NEMA Type 4-4X (IP-66) on-off control 580
(170))
63115X NEMA Type 4-4X (IP-66) on-off control 1100
(322)
63125X NEMA Type 4-4X (IP-66) on-off control 21800
(527)
63130X NEMA Type 4-4X (IP-66) on-off control 2100
(615)
63140X NEMA Type 4-4X (IP-66) on-off control 2900
(849)
60115X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 1100
(322)
60125X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 21800
(527)
60130X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 2100
(615)
60140X-316L 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 2900
(849)

 

** In 316 environments normally customers will have special filtration systems for such environments already.

 

*Cooling effect based on 95°F temperature inside cabinet, 100 PSIG (6.9 BAR) compressor inlet pressure, and 70ºF (21ºC) inlet temperature.

BTU/hr. figures rounded to nearest 100 BTU/hr (1 WATT).

All Continuous Operation models include the cooling unit, filter with auto drain and cold air distribution kit.

All On-Off control units include the cooling unit, filter with auto drain, cold air distribution kit, solenoid valve and thermostat.

+ Selection

SELECTION

Panel Coolers, Panel Cooler, Panel Air Conditioner, Cabinet Enclosure Cooler, Electrical Panel Air Conditioners, Cabinet Cooling Solution, Cooler Master Cabinet, Panel Air Conditioner, Adjustable Thermostat, Electrical Panel Coolers, How to Cool Electrical Enclosures, Electronic Temperature Control

Silent X-Stream™ NEMA 12 (IP56) Quiet Panel Coolers

Silent X-Stream™ NEMA 12 (IP56) Quiet Panel Coolers for standard cabinet enclosures and panels. All units 303/304 stainless steel for corrosive environments and long life. Super quiet to about 64 dBA. Utilizing a hot and cold end muffling kit the unit is made extra quiet to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat.

Silent X-Stream™ NEMA 3R (IP14) Quiet Panel Coolers

Silent X-Stream™ NEMA 3R (IP14) Quiet Panel Coolers for cabinet enclosures and panels in outdoor use. All units 303/304 stainless steel for corrosive environments and long life. Super quiet to about 64 dBA. Utilizing a hot and cold end muffling kit the unit is made extra quite to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat.

 

Silent X-Stream™ NEMA 4-4x (IP66) Quiet Panel Coolers

Silent X-Stream™ NEMA 4-4x (IP66) Quiet Panel Coolers for cabinet enclosures and panels in wash down applications. All units 303/304 stainless steel for corrosive environments and long life. Super quiet to about 64 dBA. Utilizing a hot and cold end muffling kit the unit is made extra quiet to under 64 dBA depending on capacity. The hot end muffler also acts a “heat guard” – you can actually wrap your hand around it without feeling much heat.

 

+ Options

Options

By-Pass System for Panel Coolers

Frigid-X™ By-Pass System for Panel

In very dirty environments, it can be advantageous to have a small amount of compressed air entering the control panel when the panel cooler is not operating (turned off utilizing a solenoid and thermostat package to conserve energy).  This is a “constant purge” system that will keep the control panel at a  slightly positive pressure all the time to prevent dirty environmental air from entering, thereby keeping the control panel clean.

Electronic Control Digital Thermostat

Electronic Temperature Control

Electronic Thermostat ELC (Electronic Control Digital Thermostat) is a way for precise control of one or two Nex Flow™ Frigid-X™ cabinet panel coolers.

Mechanical Thermostat

Mechanical Thermostat And Solenoid Valve Kit

This kit comes complete with a solenoid valve, thermostat, and a resistor. The resistor is included should you encounter rapid temperature fluctuations in the control panel causing the solenoid to cycle on and off to quickly (chattering). The resistor is installed (if needed) across the leads of the thermostat and prevents chattering by dampening the thermo switch sensitivity.

Side Mount Kit for Cabinet Panel Coolers

Side Mount Kit for Cabinet Panel Coolers

If mounting cannot be on the top of the control panel an optional Side Mount Kit for Cabinet Panel Coolers is available (except for the 316L stainless units). Enclosure Cooling System must be mounted vertical either at the top or at the side using the side mount.

+ Calculating Heat Load

Calculating Head Load

Total heat load consists of the heat transfer from outside your panel and from the heat dissipated inside the control unit.

Useful terms and conversions:

1 BTU/hr = 0.293 watts
1 BTU/hr – 0.000393 horsepower
1 Watt = 3.415 BTU/hr
1 horsepower = 2544 BTU/hr
1 Watt = 0.00134 horsepower
1 Square Foot = 0.0929 square meters
1 Square Meter = 10.76 square foot

Typical fan capacity:

4″ fan: 100 CFM (2832 LPM)
6″ fan: 220 CFM (6230 LPM)
8″ fan: 340 CFM (9628 LPM)
10″ fan 550 CFM (15574 LPM)

BTU/hr. cooling effect from fan 1.08 x (temp. inside panel in °F – temp. outside panel in degrees F) x CFM.

Watts cooling effect from fan: 0.16 x (temp. inside panel in °C – temp. outside panel in degrees C) x LPM.

Calculating BTU/hr. or Watts:

  1. Determine the heat generated inside the enclosure. Approximations may be necessary. For example, if you know the power generated inside the unit, assume 10% of the energy is dissipated as heat.
  2. For heat transfer from the outside, calculate the area exposed to the atmosphere except for the top of the control panel.
  3. Choose the internal temperature you wish to have, and choose the temperature difference between it and the maximum external temperature expected.
  4. From the conversion table that follows, determine the BTU/hr. per square foot (or watts per square meter) for the temperature difference.
  5. Multiply the panel surface area times the BTU/hr. per square foot (or watts per square meter) to get the external heat transfer in BTU/hr or in watts.
  6. Sum the internal and external heat loads calculated.
  7. If you do not know the power used in the enclosure but you can measure temperatures, then measure the temperature difference between the outside at current temperature, and the present internal cabinet temperature.
  8. Note size and number of any external fans. Provide this information to Nex Flow™  to assist in sizing the appropriate cooling system.
Temperature Difference in °F BTU/hr./sq. ft. Temperature Difference in °C Watts/sq.m
5 1.5 3 5.2
10 3.3 6 11.3
15 5.1 9 17.6
20 7.1 12 24.4
25 9.1 15 31.4
30 11.3 18 39.5
35 13.8 21 47.7
40 16.2 24 55.6

Example:

The control panel coolers has two frequency drives totaling 10 horsepower and one module rated at 100 watts. The maximum outside temperature expected is 105°F or 40.5°C. The area of the control panel cooler exposed sides, except for the top is 42 square feet or 3.9 square meters. We want the internal temperature to be 95° or 35°C.

Total internal power is 10 hp x 746 watts/hp – 7460 plus 100 watts = 7560 watts.
Assume 10% forms heat = an internal heat load of 756 watts.

Or

Total internal power is 10 hp x 2544 BTU/hp = 25440 BTU/hr plus 100 watts x 3.415 BTU/hr/watt = 25782 BTU/hr.

Assume 10% forms heat = an internal heat load of 2578 BTU/hr.

External heat load: The temperature difference between the desired temperature and the outside is 10°F or 5.5°C. Using the conversions (and interpolating where necessary) we multiply the area by the conversion factor:

42 sq. ft x 3.3 – 139 BTU/hr or 3.9 sq. m x 10.3 = 40 watts

Total Heat Load: 756 + 40 – 796 watts or 2578 + 139 – 2717 BTU/hr.

You would use a Model 61040 for constant operation or a Model 63040 for one-off control. (Rated at 2900 BTU/hr or 849 watts).

+ Pricing

FRIGID-X ELECTRONIC & ELECTRICAL ENCLOSURE COOLERS

PART NO. DESCRIPTION Size Price US Dollars
60102X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69005) $695.00
60102X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69005) $695.00
60102X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69005) $695.00
60110X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60115X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60125X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60130X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
60140X-316L-D NEMA 4-4X FRIGID-X 316L Stainless Cooler + hose kit (69004) $725.00
63102X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $692.00
63104X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $692.00
63108X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $692.00
63110X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63115X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63125X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63130X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63140X NEMA 4-4X FRIG-X Encl. Cl. + hs kit + fr + ther. (90017) & sol.(90018) – on/off control standard thermostat $714.00
63102X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,105.00
63104X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,105.00
63108X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,105.00
63110X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63115X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63125X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63130X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00
63140X-ELC NEMA 4-4X FRIG-X Encl. Cl. + hose kit + filter + ELECTR. CONTROL PACKAGED SYSTEM $1,127.00

Frigid-X™ By-Pass System for Panel cooler

PART NO. DESCRIPTION Size Price US Dollars
69700 BY-Pass System to make a contant purge systrem – One system for each cooler is necessary $180.00

MUFFING KITS FOR PANEL COOLERS

PART NO. DESCRIPTION Size Price US Dollars
69501 Cold End Muffler Kit for 10 to 40 SCFM Panel Cooler Units $90.00
69502 Hot End Muffler & Heat Guard Kit for 10 to 40 SCFM Panel Cooler Units $80.00
69503 Cold End Muffler Kit for 2 to 8 SCFM Panel Cooler Units $85.00
69504 Hot End Muffler & Heat Guard Kit for 2 to 8 SCFM Panel Cooler Units $75.00
69505 Hot and Cold End Muffler & Heat Guard Kit for 10 to 40 SCFM Panel Cooler Units $170.00
69506 Hot and Cold End Muffler & Heat Guard Kit for 2 to 8 SCFM Panel Cooler Units $160.00

Prices are in USA dollars – ex works Cincinnati, OH, USA for orders

in USA and Richmond Hill, ON, Canada for International orders.